Loading... Please wait...

Our Newsletter


Covidien Nellcor PM1000N Bedside Monitor Pulse Oximeter

  • Covidien Nellcor PM1000N Bedside Monitor Pulse Oximeter
Price:
$1,850.00
Condition:
New
Availability:
In Stock
Shipping:
Free Shipping
Minimum Purchase:
1 unit(s)
Quantity:
Bookmark and Share


Product Description

Covidien Nellcor PM1000N Bedside Monitor Pulse Oximeter

Proven Technology, State-of-the-Art Design


The Nellcor™ Bedside Respiratory Patient Monitoring System, PM1000N incorporates the latest Nellcor™ digital signal processing and cardiac-based technology for accurate, reliable readings. Because Nellcor™ pulse oximetry is closely tied to patient physiology, it drives consistent performance during various challenging conditions, such as patient movement, noise, and low perfusion which can impede the assessment of patient respiratory status. The patient monitoring system is also cleared as a motion-­tolerant bedside pulse oximeter that is compliant with ISO 80601--­2--­61.

With its intuitive, easy-to-read, graphical user interface and state-of-the-art color touch screen, this monitoring system provides clinicians with easy access to the critical information they need for patient care. The system provides continuous SpO2, pulse rate and respiration rate monitoring, SatSeconds alarm management, and Saturation Pattern Detection (SPD) alert, so clinicians may detect respiratory complications earlier and, therefore, intervene sooner.

FEATURES

- Modular software, expandable parameters and easy upgrades to help ensure long­term functionality
- State-of-the-art, lightweight and versatile design
- Multiple connectivity options
- Includes Nellcor™ Respiration Rate Technology which delivers oxygen saturation (SpO2), pulse rate, and respiration rate through a single finger sensor.
- Nellcor™ pulse oximetry with Oximax™ technology has accuracy claims of +/- 2% in the standard ranges of 70% to 100% saturation, and best-in-class LoSat accuracy claims of +/- 3% of 60% to 80%, enabling clinicians to accurately assess patients’ oxygen saturation.1,2
- The speed of measuring oxygenation and displaying the value has been shown to be clinically important. In two published papers, clinical studies employed different sequences for sensor application and connection to the patient; Nellcor OxiMax™ technology responded fastest to changes in neonate patients.1,2
- Covidien is the first and only company to receive FDA clearance for a motion-tolerant pulse oximeter portfolio that is also compliant with ISO 80601-2-61. Motion tolerant pulse oximetry is critical for ensuring patient safety because patient movement can thwart accurate readings and delay diagnosis of serious respiratory compromise.

Specifications

Performance

Measurement Range  
SpO2 1% to 100%
Pulse rate 20 to 250 beats per minute (bpm)
Pulse amplitude 0.03% to 20Accuracy


Accuracy

Saturation  
Adult 70% to 100% ±2 digits
Adult and neonate low sat 60 to 80% ±3 digits
Neonate 70 to 100% ±2 digits
Low perfusion 70 to 100% ±2 digits
Adult and neonate with motion 70 to 100% ±3 digits
Pulse rate  
Adult and neonate 20 to 250 bpm ±3 digits
Low perfusion 20 to 250 bpm ±3 digits
Adult and neonate with motion 20 to 250 bpm ±5 digits


Electrical

Instrument  
Power requirements 80-263 VAC, 47/63 Hz, 30 VA power
Fuse rating Slow blow 1.5A 250V
Battery  
Type Li-Ion
Battery capacity 6 hours under nominal load conditions


Environmental

Operating Temperature  
Instrument 5°C to 40°C (41°F to 104°F)
Transport/Storage Temperature (in shipping carton) -40°C to 70°C (-40°F to 160°F)
Operating Humidity
15% to 95% noncondensing
Operating Altitude
-304.8 m to 4572 m (-1000 ft to 15,000 ft)


Physical Characteristics

Weight
3.4kg (7.5 lbs)
Size
254 H x 165 W x 127 D (mm)
10 H x 6.5 W x 5 D (in)


Equipment Compliance

Standards Compliance  
EN ISO 80601-2-61 2011
EN IEC 60601-1 2005
EN IEC 60601-1-2 2007.03.01 3rd edition
EN IEC 60601-1-2 2nd edition
IEC 60601-1-8: 2006 and EN 60601-1-8:2007  
EN IEC 60601-1-9 2007
ISO 10993-1: 2003
CAN/CSA C22.2 No. 60601-1:08  
WEEE 2002/96/EC  
RoHS directive 2011/65/EU  


Equipment Classifications

Type of protection against electric shock Class 1 (internally powered)
Degree of protection against electric shock Type BF - Applied part
Mode of operation Continuous
Electromagnetic compatibility IEC 60601-1-2:2007 3rd edition
Liquid ingress IPX1
Degree of safety Not suitable for use in the presence of flammable anesthetics


Output

Stores up to 48 hours of trend data readings that can be downloaded for analysis and archive
Capability to connect to both wired and wireless LAN networks
Capability to connect to Philips Vuelink Module and Nurse Call via wired serial port
Capability to download trend data to PC


Display/Indicators

Pulse Amplitude Indicator (16 segments)
Plethysmographic waveform
Real time numbers
Real time trend data
Multiple alarm conditions
Up to 3 alarm conditions simultaneously
SatSeconds Alarm Management
OxiMax SPD Alert
Battery Charging
Clock
Event Marker
Histogram Display
Clinical Log
Neonatal Default Mode


Alarms

Audible and visual alarms for high/low saturation and pulse rate
SatSeconds Alarm Management settings: 10,25,50 and 100, or OFF
Saturation Pattern Detection sensitivity setting: 1,2,3 or OFF
Pulse Rate Delay settings: 5, 10 or OFF
Audible and visual warning indicators for low battery and sensor off
Audible and visual sensor disconnect alarms
Communication failure visual alarm
Backup audible alarm
Variable pitch beep tone for point-by-point changes in SpO2
User configurable sensor alarm prioritization


Optional Accessories

GCX mounting adapter
Interface cable




Find Similar Products by Tag


Find Similar Products by Category


Write your own product review

Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!


Add to Wish List

Click the button below to add the Covidien Nellcor PM1000N Bedside Monitor Pulse Oximeter to your wish list.

You Recently Viewed...